Power Division

Static Inverter28VDC → 230VAC / 50Hz

A 500–1200VA true-sinewave static inverter engineered for FAA TSO-C73 / EASA ETSO-C73 platforms requiring stable 230VAC, 50Hz power from a 28VDC bus. Low RDS(on) MOSFETs and synchronous rectification deliver 92% efficiency, permitting a smaller heatsink and single-fan cooling at 6 lb max — with inrush, OV/UV, and over-frequency protection beyond typical competitive coverage.

1200VA continuous  ·  1800VA overload (5 min)  ·  92% efficiency
500–1200VA
Output Power
230VAC
Output Voltage
50Hz ±0.5Hz
Frequency
92%
Efficiency
6.25 lb
Max Weight
Static Inverter 50Hz unit photo
The Hardware

One rugged inverter unit

A single sealed housing converts 28VDC bus power into stable 230VAC, 50Hz output — no external conversion stages to integrate. Higher efficiency permits a smaller heatsink and single-fan cooling at 6 lb max.

92% Efficiency Single-Fan Cooling TSO-C73 / ETSO-C73
Differentiators

Why it outperforms

Company A
Company B
APN
Input Voltage, VDC
20 – 36.5
20 – 36
18 – 36.5
Output Voltage
230VAC ± 2.5%
230VAC ± 3%
230VAC ± 2%
Output Frequency
50Hz ± 0.6Hz
50Hz ± 0.6Hz
50Hz ± 0.5Hz
Power Factor
+0.8 to -0.8
+0.8 to -0.8
+0.8 to -0.75
Continuous Power
1200VA
1200VA
1200VA (1320VA @ sea level)
Overload
1320VA / 2 hrs, 1800VA / 5 min
1800VA (current limit)
1800VA / 5 min, 2kVA / 5 sec
THD
0.5% (nominal)
< 3%
0.50%
Operating Temp.
-55°C to 71°C
-55°C to 70°C
-55°C to 71°C
Efficiency (nominal)
87%
88%
92%
Weight
7.7 lb (3.5 kg)
7.3 lb (3.31 kg)
6 lb (2.72 kg)
Applicable Platforms

Where it fits

The Static Inverter's 28VDC input, single-phase 230VAC/50Hz output, and TSO-C73 / ETSO-C73 qualification suit it for forward-fit and retrofit installations across a broad range of 28VDC-bus platforms.

01 / Rotorcraft

Rotorcraft

  • Aerial firefighting
  • Search & rescue
  • Utility
  • Law enforcement
02 / Business Jets

Business Jets

  • Light & super-versatile jets
  • Cabin & galley power
  • Avionics buses
  • Retrofit & forward-fit
03 / Military

Military & Government Aircraft

  • Tactical transport
  • Special mission
  • ISR
  • Government / VIP
04 / Ground

Ground Support & Test Equipment

  • Ground power units
  • Avionics test benches
  • MRO & depot test
  • Maintenance stands
Documentation

Technical specifications

01Input Voltage+
Nominal28VDC
Normal22–30.3VDC
Abnormal20.5–36.4VDC
Emergency18V
02Output Characteristics+
Output28VDC → 230VAC, 50Hz
Continuous Power1200VA (1320VA @ sea level)
Overload1800VA for 5 minutes
Power Factor> 0.75
Power QualityPer MIL-STD-704F
Waveform / THDTrue sinewave, <0.5%
Efficiency92% at nominal power
03Environmental+
Altitude55,000 ft
Ambient Temperature-55°C to 71°C
Humidity10 days @ 95%
OtherTemperature shock, vibration, shock, RF emission, induced lightning transients, flammability
04Protection+
OutputOvervoltage & undervoltage
Output FrequencyOver-frequency >65Hz, under-frequency <55Hz
Overload> 7 sec
InternalOvertemperature
05Electrical Interface+
ConnectorMS3102A24-12P
Remote ControlIncludes remote ON/OFF
06Physical & Reliability+
Dimensions10.6" × 6.34" × 3.5" (L×W×H)
Weight6.25 lb max (2.83 kg)
MTBF> 20,000 hrs
07Qualification & Certification+
StandardsRTCA DO-160G, FAA TSO-C73, EASA ETSO-C73
PDF
Static Inverter 50Hz Datasheet
Full performance and interface specifications
Request Datasheet
Get in touch

Talk to a power
systems engineer

From datasheet questions to evaluation units, our team can help scope this product for your platform.

×
Technical resources

Request a datasheet

Tell us where to send the datasheet. Email and company are required.

We’ll use these details to respond to your datasheet request.

Thank you. Your datasheet request has been received. Our team will follow up by email.
Your request could not be sent. Please check your details and reCAPTCHA, then try again.